Efficient energy usage. The innovative blade geometry and energy-efficient IE3/IE4 motors ensure the best possible specific thrust coefficient. At the same time, this reduces your energy and operating costs.
Consistently reliable. The low-wearing GFK/PA6 propeller is durable and scores with its self-cleaning effect.
Smooth running thanks to the balanced propeller load, even in high thrust ranges and when incoming flow conditions are unfavourable.
Axial pump submersible without cooling system for continuous duty in pipe chambers in the stationary wet well installation.
Pumping of
Pre-cleaned sewage without faeces and long-fibre components
Process water
Wastewater
Process water
Heavy-duty version made of grey cast iron
Mains connection: 380 V, 50 Hz
Submerged operating mode: S1
Protection class: IP68
Max. fluid temperature: 3 - 40°C; higher temperatures on request
Free ball passage: 85 – 130 mm.
Permanently lubricated roller bearings
Max. immersion depth: 20 m
Housing components: EN-GJL
Propellers: Stainless steel
Sealing on pump side: SiC/SiC
Sealing on motor side: SiC/SiC
Static gaskets: NBR
Shaft: Stainless steel 1.4021
Axial submersible pump as submersible monobloc unit for stationary wet installation
Hydraulics
The angle of the propeller/impeller blades can be adjusted by hand. This makes it possible to adapt the unit to use in different conditions.
Motor
Surface-cooled motors (T motors) give off their heat directly to the surrounding fluid via the housing components and can be used in immersed state for continuous duty.
A sealing chamber protects the motor from fluid ingress. It can be accessed from the outside and can be monitored with an optionally sealing chamber electrode.
All filling fluids used are potentially biodegradable and environmentally safe.
The cable inlet of the T motors is longitudinally watertight. Cable lengths can be individually configured.
Seal
Fluid-side and motor-side sealing is possible in the following versions depending on the motor type:
Version G: Two independently-acting mechanical seals
Version K: Block seal cartridge with two independently acting mechanical seals
Axial submersible pump
Cable length as per customer request
Accessories according to customer request
Operating and maintenance manual
Special voltages
PTC thermistor sensor
Internal or external sealing chamber monitoring
Monitoring units for leakage and bearing temperature
Switchgear, relays and plugs
Operation with non-immersed motor:
Surface-cooled motors (T motors) can be non-immersed only if an operating mode is specified for non-immersed operation!
Dry-running protection system:
The hydraulics housing must always be immersed to prevent air from being drawn in. In the case of fluctuating fluid levels, the system should shut down automatically once the minimum water submersion is reached.