Custom Wilo DrainLift Box Equipment For Lifting Sewage Pumping

Ask Latest Price
Video Channel
Brand Name :Wilo
Model Number :DrainLift BOX
Place of Origin :Germany
MOQ :1
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :Peak Season Lead Time: 1-3 months ,Off Season Lead Time: 1 month
Delivery Time :5-8 weeks
Packaging Details :Standard Export Plywood Case or Carton
Frequency :50Hz
Usage :Residential/Commercial
Max Temperature :40℃
Voltage :220V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Wilo DrainLift box Equipment For Lifting Sewage Inside Buildings

Company Info

Address: Tianjin, China

Business Type: Trading Company
Business Range:Auto, Motorcycle Parts & Accessories, Bags, Cases & Boxes, Electrical & Electronics, Health & Medicine, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Packaging & Printing, Service, Tools & Hardware
Management System Certification:ISO 9001
Main Products: Water Pump Set
Company Introduction:Tianjin Shiny-Metals Technologyco., Ltd., situated in Tianjin, China, is a professional enterprise specializing in pump research and development, design, production, sales, trade, and service. Currently, our products have been exported to over 40 countries and regions, consistently enhancing our global brand reputation. We manufacture a diverse range of pumps, including centrifugal pumps, axial flow pumps, jet pumps, submersible pumps, deep-well submersible pumps, and swimming pool pumps, spanning over 500 specifications. We have obtained the ISO 9001 certification from the International Organization for Standardization (CQC). Additionally, our civilian motors have undergone product evaluation for CCC China mandatory certification. Furthermore, we have achieved certifications such as CE, EMC, GS, RoHS, EAC, SASO, and ST. Our company fulfills customer needs with high-quality products, reasonable prices, and exceptional pre-sales, in-sales, and after-sales services. Adhering to the management principles of "quality first, customer first, and reputation-based", we are committed to providing global customers with the best water pump and water treatment system solutions, enhancing their quality of life. Our pursuit is "water makes the world a better place, we make water even better"

Product Description

Wilo DrainLift BOX is a device used for lifting sewage in buildings. It is compact in design, easy to install, and easy to maintain. Some models of sewage pumps have anti sedimentation and deodorization functions.

Mains connection: 1~230 V, 50 Hz

Discharge connection: 40 mm

Inlet connection: 110 mm (DN 100)

Ventilation connection: 110 mm (DN 100)

Aplication field :The Wilo DrainLift BOX is used as a lifting device (ground mounted) or pump room (concealed floor mounted) inside buildings to discharge sewage from drainage points below the reflux level or drainage points that cannot be naturally drained downhill, ensuring smooth drainage of sewage inside buildings and avoiding water accumulation and sewage backflow problems.
Suitable for collecting and pumping sewage without feces in household areas, in compliance with relevant standards for sewage pumping (such as EN 12050-2), playing a key role in sewage discharge systems in homes, commercial buildings, and other places.

Custom Wilo DrainLift Box Equipment For Lifting Sewage Pumping

Your advantages

  • Easy to install due to integrated pump and non-return valve
  • The large tank volume ensures a low number of switching processes
  • Easy maintenance
  • Stainless steel tile frame with trap

Design

Compact and fully-automatic sewage lifting unit for above-ground and concealed floor installation within buildings.

Application

  • As a lifting unit within buildings (floor-mounted installation)
  • As a pump chamber within buildings (concealed floor installation)
  • For backflow resistant drainage of
    • Drainage points below the backflow level
    • Drainage points that cannot be drained via the natural downward slope.

Liquid

For collection and pumping of the following in domestic areas:

  • Sewage not containing faeces

Sewage pumping according to 12050

The pumps meet the requirements of EN 12050-2.

Equipment/function

DrainLift BOX ...

  • Submersible pump with thermal motor monitoring
  • Fitted float switch
  • Ready-to-plug

DrainLift BOX ... D

  • Submersible pump with thermal motor monitoring
  • Fitted float switch
  • Ready-to-plug

DrainLift BOX ... DS

  • Submersible pump with thermal motor monitoring
  • Separate float switch in pump chamber
  • Switchgear with mains-independent alarm and collective fault signal

Typekey

Example:

Wilo-DrainLift BOX-32/11HD DS O

BOX

Sewage lifting unit for sewage free of faeces

32

Nominal diameter discharge connection of the installed pump

11

Max. delivery head in m

HD

HD = Pump for aggressive fluids

D

Lifting unit version:

  • E = Single-pump system

  • D = Double-pump system

S

Pump control:

  • Without = Pump with float switch

  • S = Switchgear with float switch

O

Installation type:

  • O = Floor-mounted installation

  • U = Concealed floor installation

Technical data

  • Mains connection: 1~230 V, 50 Hz
  • Discharge connection: 40 mm
  • Inlet connection: 110 mm (DN 100)
  • Ventilation connection: 110 mm (DN 100)
  • Tank volume: 113 l
  • Switching volume: 22 … 30 l
  • Switchgear protection class (for DS version): IP54

Materials

DrainLift BOX-32 ...

  • Pump chamber:
    • Tank: PE
    • Pipework: PE
    • Non-return valve: PE
  • Pump:
    • Pump housing: PP-GF30
    • Motor housing: 1.4301 (AISI 304)HD version: AISI 316L
    • Impeller: PPE/PS-GF20
    • Seal on the motor side: NBR
    • Seal on the fluid side: C/SIC (BQ1PFF)
    • Static seal: NBR

DrainLift BOX-40 ...

  • Pump chamber:
    • Tank: PE
    • Pipework: PE
    • Non-return valve: PE
  • Pump:
    • Pump housing: EN-GJL-200 (ASTM A48 Class 30)
    • Motor housing: 1.4301 (AISI 304)
    • Impeller: PK-GF30
    • Seal on the motor side: NBR
    • Seal on the fluid side: C/MgSi (BXPFF)
    • Static seal: NBR

Construction

DrainLift BOX-32 ... and DrainLift BOX-32 ... D ...

Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.

Sewage pump with integrated turbulator (twister function), open multi-channel impeller and vertical threaded connection. Pump housing, strainer and impeller made of composite material. 1~ motor (jacket cooling) with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Connection cable with float switch and fitted plug (CEE 7/7).

The twister function guarantees permanent turbulence within the pump's intake area. The turbulence prevents the settling sediments from sinking and settling. This ensures a clean pump sump and reduces the build-up of odours.

The level control takes place via the float switch attached to the pump. The “pump on/off” switching level is determined by the cable length of the float switch.

DrainLift BOX-32 ... DS ...

Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.

Sewage pump with integrated turbulator (twister function), open multi-channel impeller and vertical threaded connection. Pump housing, strainer and impeller made of composite material. 1~ motor (jacket cooling) with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Connection cable with float switch and fitted plug (CEE 7/7).

The twister function guarantees permanent turbulence within the pump's intake area. The turbulence prevents the settling sediments from sinking and settling. This ensures a clean pump sump and reduces the build-up of odours.

The level control takes place via the separate float switch in the tank and a switchgear. The switchgear is preset. The “pump on” switching point is determined by the cable length of the float switch. The “pump off” switching point is defined by the set follow-up time in the switchgear. The switchgear offers the following functions:

  • Collective fault signal (SSM)

  • High water alarm – additional float switch available as an accessory

  • Integrated buzzer, mains-independent – 9 V rechargeable battery included in the scope of delivery

DrainLift BOX-40 ... and DrainLift BOX-40 ... D ...

Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.

Sewage pump with vortex impeller and vertical threaded connection. Hydraulics housing made of grey cast iron, impeller made of plastic. Surface-cooled 1~ motor with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Detachable connection cable with float switch and fitted plug (CEE 7/7).

The level control takes place via the float switch attached to the pump. The “pump on/off” switching level is determined by the cable length of the float switch.

DrainLift BOX-40 ... DS ...

Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.

Sewage pump with vortex impeller and vertical threaded connection. Hydraulics housing made of grey cast iron, impeller made of plastic. Surface-cooled 1~ motor with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Detachable connection cable with fitted plug (CEE 7/7).

The level control takes place via the separate float switch in the tank and a switchgear. The switchgear is preset. The “pump on” switching point is determined by the cable length of the float switch. The “pump off” switching point is defined by the set follow-up time in the switchgear. The switchgear offers the following functions:

  • Collective fault signal (SSM)

  • High water alarm – additional float switch available as an accessory

  • Integrated buzzer, mains-independent – 9 V rechargeable battery included in the scope of delivery

Scope of delivery

DrainLift BOX ... E

  • Plastic chamber with installed pipework
  • Pipework with non-return valve
  • Pump with float switch and plug
  • Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
  • O-ring to seal tank cover and as anti-syphon trap
  • Concealed floor installation
    • Tank cover with tile frame and floor drain
    • Shell cover
  • Floor-mounted installation
    • Tank cover (cover plug)
    • Fixation material for buoyancy safeguards
  • Installation and operating instructions

DrainLift BOX ... D

  • Plastic chamber with installed pipework
  • Pipework with non-return valve and Y-piece
  • Two pumps with float switch and plug
  • Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
  • O-ring to seal tank cover and as anti-syphon trap
  • Concealed floor installation
    • Tank cover with tile frame and floor drain
    • Shell cover
  • Floor-mounted installation
    • Tank cover (cover plug)
    • Fixation material for buoyancy safeguards
  • Installation and operating instructions

DrainLift BOX ... DS

  • Plastic chamber with installed pipework
  • Pipework with non-return valve and Y-piece
  • Two pumps with plug
  • Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
  • O-ring to seal tank cover and as anti-syphon trap
  • Concealed floor installation
    • Tank cover with tile frame and floor drain
    • Shell cover
  • Floor-mounted installation
    • Tank cover (cover plug)
    • Fixation material for buoyancy safeguards
  • Switchgear with float switch and plug
  • 9 V rechargeable battery
  • Installation and operating instructions

Accessories

  • Collar − to stop ground water from seeping into the concealed floor installation.
  • Alarm switchgears − to detect leakages.
  • Float switch − to detect high water levels.
  • Diaphragm pump − for emergency draining.
  • Stop valve
Inquiry Cart 0