Brand Name :Wilo
Model Number :Wilo-SiFire Easy
MOQ :1
Price :Negotiable
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :100
Delivery Time :within 15 workdays
Packaging Details :Wooden Box
Mains connection :3~400 V, 50 Hz (1~230 V, 50 Hz for the control panel of the diesel pump)
Max. ambient temperature :+4 °C to +40 °C (+10 °C to +40 °C, if a diesel pump is installed)
Max. fluid temperature :+25 °C
Max. operating pressure :10 or 16 bar
Max. inlet pressure :6 bar
Volume flow :10 m³/h to 750 m³/h
Maximum head :120h/m
Maximum.flow :750m³/h
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Wilo-SiFire Easy Fully Equipped Fire Fighting System For Hotels Hospitals And Shopping Centres

Your advantages

  • Pressure-loss optimised system designed in accordance with the EN 12845 standard with electrical or diesel drive, jockey pump for maintaining system pressure
  • Flexible, modular and solid construction for safe transport and simple installation
  • Bypass volume flow for the protection of the pump with spacer coupling for simple maintenance
  • Optimum regulation and ease of use via EC-Fire control with direct display of the current operating status
  • Special baseplate for minimal vibrations, cable laid in the construction in such a way as to ensure maximum reliability and service life

Wilo SiFire Fire Water Pumps System Firefighting Pump For Hotels Hospitals

Design

Pressure-boosting systems for firefighting according to EN 12845. Consists of 1 or 2 pumps, depending on the module, with horizontal baseplate - EN 733 - with spacer coupling, electric or diesel motor and a multistage, vertical electric jockey pump.

Application

Fully automatic water supply for fire-fighting systems with sprinklers in domestic, commercial and public buildings, hotels, hospitals, shopping centres and industrial buildings.

Equipment/function

  • One or two pumps with a horizontal base frame from the series 32-200 to 150-315, with an IE-equivalent standard motor or diesel motor
  • With a diaphragm installed directly on the main pump housing to prevent overheating in the event of zero flow
  • Jockey pump of Medana CV1-L series with pressure switch and vertical pressure tank 20 l, PN 16
  • One switch cabinet per pump, fixed to a robust support structure. Model EC-Fire E for the electric motor and D for the diesel motor, both equipped with Easy Controller, plus J for the jockey pump
  • Base frame made of electro-galvanised steel with height-adjustable holder for the outlet manifold
  • Pipework made of steel; painted with epoxy resin. Manifold with flanges
  • Shutting gate with safety lock on the discharge side of each pump
  • Swing check valve on the discharge side of each pump
  • A circuit with dual pressure switch, pressure gauge, swing check valve, valve for the main pump and standby pump for automatic start
  • Concentric cone on the discharge side of the main and standby pump, for speed limitation according to the parameters specified in EN 12845
  • DN 2" connection for the supply tank of the pumps
  • Pressure measurement on the discharge side
  • Only for the model with diesel motor:
    • Vibration damping sleeve on the discharge side of the pump
    • Vibration damper under the base frame of the pump
    • Fuel tank with level sensor and sufficient volume for six hours of autonomous operation
    • Two batteries on the base frame and battery charger in the EC-Fire switchgear
  • Accessories upon request: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Horizontal 500 l supply tank, with float valve and pressure switch for LL-alarm (water shortage)
    • Flow meter: Kit with eccentric cone on the suction side, complete with butterfly valve with hand lever or handwheel
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Vibration damping sleeve for the manifold
    • Remote control panel for transmitting level A and level B alarms
    • Density meter for battery
    • Spare parts kit for the diesel motor
    • Silencer (30 dBA) for the diesel motor
    • Hydraulic heat exchanger for the diesel motor

Typekey

Example: Wilo-SiFire Easy 40/200-180-7.5/10.5 EDJ
SiFire Compact pressure-boosting system for firefighting equipment
Easy Easy handling and in accordance with the EN 12845 standard
40/200 Type of main pump
180 Actual impeller diameter of the main pump
7.5 Power of the electric motor [kW] *
10.5 Power of the diesel motor [kW] *
EDJ Configuration
E One electric pump
D One diesel pump
J One jockey pump
* = minimum motor power, do not fall below

Technical data

  • Mains connection 3~400 V, 50 Hz (1~230 V, 50 Hz for the control panel of the diesel pump)
  • IE equivalent standard motors, diesel motor with direct injection or turbo diesel motor with air or water cooling
  • Max. ambient temperature +4 °C to +40 °C (+10 °C to +40 °C, if a diesel pump is installed)
  • Max. fluid temperature +25 °C
  • Max. operating pressure 10 or 16 bar
  • Max. inlet pressure 6 bar
  • Volume flow 10 m³/h to 750 m³/h
  • Max. delivery head 128m
  • Nominal connection diameters on the discharge side DN 65 to DN 250
  • Nominal connection diameters on the intake side DN 50 to DN 200
  • Switch cabinet protection class IP54
  • Main/standby pump with horizontal base frame in accordance with EN 733
  • With epoxy resin painted piping and hydraulic connections
  • Permissible fluids: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Non-aggressive, clean water
    • Firefighting water

Materials

For the pump with a horizontal base frame, depending on the model

  • Impellers made of bronze CuSn10 or CuAl10Fe5Ni5 or stainless steel AISI 316/ 1.4401
  • Pump housing made of grey cast iron EN-GJL-250
  • Shaft made of stainless steel AISI420/1.4021 or AISI 431/ 1.4057
  • Neck rings made of stainless steel AISI316L/1.4409 or bronze

For the jockey pump

  • Impellers made of stainless steel AISI 304/ 1.4301
  • Pump housing made of stainless steel AISI304/1.4301
  • Shaft made of stainless steel AISI 304/ 1.4301
  • O-ring seals made of EPDM